Cannot connect to nbsl
WebJun 23, 2015 · A successful connection to nbsl: ErrorHandler---> (getApplicationsManager) Status Code: 0 -> . vrts.nbu.admin.icache.NBGUIORBConfigurator:rhmaster:1556:nbsl [19-06-2015 19:37:51:467] jacorb.orb.giop:INFO: ClientConnectionManager: found ClientGIOPConnection to rhmaster:1556:nbsl (6f8cf13b) ICACHE.PBXIOPCredsHandler … WebSep 19, 2024 · Intermittently, it is not possible to connect to NetBackup (NB) services on the master server via port 1556/PBX. If this condition exists for 30+ minutes the storage servers may be marked down/off-line and backup jobs will begin to fail with status 2106. Existing connections continue to work.
Cannot connect to nbsl
Did you know?
WebNov 22, 2013 · Looks lik NetBackup Service layer (NBSL) process has problem; hope restarted nbsl should help. 21-11-2013 21:26:12:534] pbxiop:INFO: createSocket - Trying to connect to nbumaster:1556:nbsl [21-11-2013 21:26:12:535] pbxiop:INFO: Connected to exchange at:nbumaster:1556:nbsl [21-11-2013 21:26:12:540] pbxiop:ERROR: … WebJun 22, 2024 · nbsl; nbatd; NB_dbsrv (on UNIX) or the dbsrv16 (on Windows) Note: For more details on NetBackup commands, refer to the NetBackup Commands Reference Guide. Start the nbsl and nbatd services, if they are not running. Start the NB_dbsrv (on Unix) service or the dbsrv16 (on Windows) service, if it is not running.
WebFeb 27, 2008 · Unable to connect to the NetBackup service layer service (NetBackup Service Layer Daemon) on host , it failed to respond - Server connection failed. Verify services or daemons are up and running (195). Details: Overview: The above problem can occur when going to view media or volume pools if nbsl terminates during normal … WebFeb 12, 2015 · 14:34:44.116 [239534] <16> DevConfigCLI::analyzeOp: failed to preview disk volumes, cannot connect on socket 14:34:44.122 [239534] <2> nbdevconfig: Exiting, status = 25 . The rsrcevtmgr service (OID 219, logs to nbemm) indicates that the master server (nbmaster, in this example) is unable to send a config response to the Media Server:
WebJun 8, 2016 · "Could not connect to Netbackup Service Layer, You will be rre-directed to Backup , Archive and Restore User interface" Details of Master server. HARDWARE LINUX_RH_X86 VERSION NetBackup 7.6.0.4 RELEASEDATE Fri Oct 24 23:07:58 CDT 2014. I checked whether nbsl is running ( restrted it ) nbatd (running),still the issue persist. WebSep 24, 2024 · It looks like nbsl is not handling the query within the timeframe. Error: ErrorHandler---> (aqueryFacet) Status Code: 0 -> . NBGUIORBConfigurator : gf0zsxba040v:1556:nbsl_secsvc ICACHE.NBSLLoggingContextInterceptor-> Request ID 30 for Corba API Symantec.NetBackup.SL.DeviceMgmt.DriveQueryFacet.getGlobalInfo
WebJan 14, 2024 · Attempts to connect to NetBackup with the Java administration console result in error: Could not connect to NetBackup Service Layer. You may not be able to perform the functions in the Administration Console that depends on connectivity to this service. Please ensure the nbsl service is up and running. Cause. Missing Virtual …
WebJul 1, 2024 · Install_Path/netbackup/bin/nbsl -terminate. Install_Path/netbackup/bin/nbsl. To stop vnetd and NB_dbsrv, refer to the following … poor nfl playersWebBristol Blues on the NECBL Network Live and On-Demand Video Streaming from the New England Collegiate Baseball League poor new yorkWebAug 23, 2012 · Remove invalid Hyper-V host from policy or delete the policy as deactivating the policy will still allow the connection attempt to be made. Formal Solution: The behavior mentioned up top will be fixed with the following releases, OpsCenter 7.5.0.4 and OpsCenter 7.6 Applies To Netbackup 7.1.0.3 Opscenter 7.1.0.3 References Etrack : ET2852958 poorni healthcare pvt ltdWebApr 30, 2013 · The verbose (-v) argument to bptestnetconn also caused a connection to the bpcd process on the media server. This is a single connection to prove bpcd is reachable, and does not attempt to bring up a a call-back connection so the bpcd debug log shows the initial connection and then a failure when bptestnetconn closes the initial socket without … poor night vision causesWebAug 28, 2012 · Socket connect fails Cause The nbsl (NetBackup Service Layer) process did not appear to be responding. Solution Stop the nbsl process cleanly and then restart the nbsl process. UNIX/Linux: /usr/openv/netbackup/bin/nbsl -terminate /usr/openv/netbackup/bin/nbsl Windows: install_path\Veritas\NetBackup\bin\nbsl … share my files appWebDec 20, 2024 · For account security, your password must meet the following criteria: At least ten (10) characters, A lowercase letter, An uppercase letter, A number, A symbol, Does … poor night vision medical termWebNov 14, 2012 · For account security, your password must meet the following criteria: At least ten (10) characters, A lowercase letter, An uppercase letter, A number, A symbol, Does not include your username, Is not any of your last 4 passwords. New password sharemyfiles bureau veritas